Features:
6 probe can be used (F400, F1, F1/90 ¡ã, F10, N1, CN02) were measured; Three calibration methods: one-point calibration, two-point calibration, the basic calibration; Display Resolution: 0.1¦Ìm (measuring range is less than 100¦Ìm) 1¦Ìm (measurement range greater than 100¦Ìm) There are two modes: direct mode and burst mode There are two measurements: continuous measurement and the single measurement There are two shutdown modes: manual and automatic shut off Can be set to gauge: The gauge can be measured outside the automatic alarm, and the histogram of the number of measurements available for analysis; A delete function: Set on the gross error and error handling can be deleted; Print function: print measurement measurements, statistics, gauge, histogram
Specifications:
Type |
CTG2100F |
CTG2100N |
CTG3100 |
CTG4100 |
Measuring principle |
Magnetic |
Eddy |
Magnetic/Eddy |
Magnetic/Eddy |
Measuring range |
Standard probe£¨F1/N1)£º1¡«1250¦Ìm |
Accuracy |
¡À£¨2%H+1£©¦Ìm£¨Zero calibration £© ¡À[(1¡«3)%H+1] ¦Ìm£¨Two-point calibration £© |
Statistics |
Mean (MEAN), maximum (MAX), minimum (MIN), the number of tests (NO), standard deviation (S. DEV) |
Storage and statistics |
15 measurements |
Accuracy |
¡À (2% H +1) ¦Ìm (zero calibration) ¡À [(1 ~ 3)% H +1] ¦Ìm (two-point calibration) |
Zero calibration |
¡Ì |
¡Ì |
¡Ì |
¡Ì |
Two-point calibration |
¡Ì |
¡Ì |
¡Ì |
¡Ì |
Delete function |
¡Ì |
¡Ì |
¡Ì |
¡Ì |
Automatic shutdown |
¡Ì |
¡Ì |
¡Ì |
¡Ì |
Beep Tips |
¡Ì |
¡Ì |
¡Ì |
¡Ì |
Measurement |
¡Ì |
¡Ì |
¡Ì |
¡Ì |
Voltage indication |
¡Ì |
¡Ì |
¡Ì |
¡Ì |
Error
Tips |
¡Ì |
¡Ì |
¡Ì |
¡Ì |
|
|
|
|
|
Standard delivery |
Main unit |
Main unit |
Main unit |
Main unit |
|
F1 probe |
N1 probe |
F1(N1) probe |
F1(N1) probe |
|
Matrix Calibration sheet Manual Box |
Matrix Calibration sheet Manual Box |
Matrix Calibration sheet Manual Box |
Matrix Calibration sheet Manual Box |
Optional accessary |
F1¡¢F400¡¢F10 probe N1¡¢N400 probe |
Communication Software F1¡¢F400¡¢F10 probe N1¡¢N400 probe |
Probe model |
F400 |
F1 |
F1/90o |
F10 |
N1 |
CN02 |
Operating principle |
Magnetic induction |
Eddy current |
Measuring range (¦Ìm) |
0-400 |
0-1250 |
0-10000 |
0 to 1250 ¦Ìm 0 to 40¦Ìm (for chromeplate on copper) |
10~200 |
Low range resolution (¦Ìm) |
0.1 |
0.1 |
10 |
0.1 |
1 |
Accuracy |
One-point calibration (¦Ìm) |
¡À(3%H+1) |
¡À(3%H+10) |
¡À(3%H+1.5) |
¡À(3%H+1) |
Two-point calibration (¦Ìm) |
¡À[(1~3)H%+0.7] |
¡À[(1~3)H%+1] |
¡À[(1~3)%H+10] |
¡À[(1~3)%H+1.5] |
- |
Measuring conditions |
Min curvature of the min area (mm) |
Convex |
1 |
1.5 |
Flatten |
10 |
3 |
Flatten |
Diameter of the min area (mm) |
¦Õ3 |
¦Õ7 |
¦Õ7 |
¦Õ40 |
¦Õ5 |
¦Õ7 |
Critical thickness of substrate (mm) |
0.2 |
0.5 |
0.5 |
2 |
0.3 |
unlimited | |