Features:
*Two measuring methods: magnetic induction (F) and eddycurrent (N) *2 measurement modes: continuous / single *5 types of probes can be used (F400, F1, F10, N1, CN02,)£» *5 statistical ways: Mean values / Max. values / Min. values / testing numbers.(No.) / standard deviations (S.DeV) *5 statistic values£ºmean value£¨MEAN£©, max. value£¨MAX£©, min. value£¨MIN£©, numbers of measuring£¨NO£®£©, standard deviation£¨S£®DEV£©£» *Direct testing mode and block statistics mode (APPL/BATCH) *Direct print out of statistical values *Low battery indication *2 switch off modes: manual and auto *The instrument caters for the demands as follows:GB/T 4956©¤1985 GB/T 4957©¤1985 JB/T 8393©¤1996 JJG 889©¤95 JJG 818©¤93 *Application fields : Electroplating industry, Spray-painting and plastic-painting industry ,Aluminum processing industry, Pipeline industry, *Car manufacture industry Steel construction and color steel plate industry *The CTG2600 dataview software with USB interface is in the standard delivery for the customer
Specifications:
Measuring range |
Refer to the below table1¡¢table 2 |
Probes available |
Tolerance |
Minimum resolution: |
Measuring condition |
Operation language |
English |
Standards |
DIN, ISO, ASTM,BS |
Calibration |
Zero and foil calibration |
Statistics |
Number of measurements, mean, standard deviation,maximum and minimum of 3000 readings |
Data memory |
495 readings |
Humidity: |
20%¡«90%RH |
Environment of application: |
0-40¡æ (No strong magnetic field) |
power supply |
2¡Á1.5V AA |
Dimensions |
1250mm¡Á67 mm¡Á31 mm |
Weight |
400g |
Standard configurations:
Main unit |
1 |
Probe |
1 |
Standard test plate |
5 |
Substrate |
1 |
Carrying Case |
1 |
Operation Manual |
1 |
Optional probes and technical specification
Table 1
Probe model |
F400 |
F1 |
F1/90¡ã |
F5 |
F10 |
Operating principle |
Magnetic induction |
Measuring range (mm) |
0¡«400 |
0¡«1250 |
0¡«5000 |
0¡«10000 |
Low range resolution(mm) |
0.1 |
0.1 |
1 |
10 |
Accuracy |
One-point calibration (mm) |
¡À(3%H+1) |
¡À(3%H+5) |
¡À(3%H+10) |
Two-point calibration (mm) |
¡À((1¡«3)%H+0.7) |
¡À((1¡«3)%H+1) |
¡À((1¡«3)%H+5) |
¡À((1¡«3)%H+10) |
Measuring conditions |
Min curvature radius (mm) |
Convex |
1 |
1.5 |
Flatten |
5 |
10 |
Diameter of the min area (mm) |
F3 |
F7 |
F7 |
F20 |
F40 |
Critical thickness of substrate (mm) |
0.2 |
0.5 |
0.5 |
1 |
2 |
Table 2
Probe model |
N400 |
N1 |
N1/90¡ã |
CN02 |
N10 |
Operating principle |
Eddy current |
Measuring range (mm) |
0¡«400 (Chrome on copper |
0¡«1250 0¡«40) |
10¡«200 |
0¡«10000 |
Low range resolution(mm) |
0.1 |
0.1 |
1 |
10 |
Accuracy |
One-point calibration (mm) |
¡À(3%H+0.7) |
¡À(3%H+1.5) |
¡À(3%H+1) |
¡À(3%H+25) |
Two-point calibration (mm) |
¡À[(1¡«3)%H+0.7] |
¡À[(1¡«3)%H+1.5] |
___ |
¡À[(1¡«3)%H+25] |
Measuring conditions |
Min curvature radius (mm) |
Convex |
1.5 |
3 |
Flatten |
Only flatten |
25 |
Diameter of the min area (mm) |
F4 |
F5 |
F5 |
F7 |
F50 |
Critical thickness of substrate (mm) |
0.3 |
0.3 |
0.3 |
No limit |
50mm aluminum foil |
|