Search£º
Categories
 
Information
 
Ultrasonic Flaw Detectors
SUD360 Digital Ultrasonic Flaw Detector
Features

*Automated gain¡¢Peak Hold and Peak Memory£»
*Automated display precise flaw location(Depth d¡¢level p¡¢distance s¡¢amplitude¡¢sz dB¡¢§æ)£»
*Ten independence setup, any criterion can be input freely, we can work in the scene without test block£»
*Big memory of 300 A graph and 30000 thickness value.
*Gate and DAC alarm£»Acoustic-Optical alarm;
*RS232 port£¬communication with pc is easy£»
*The embeded software can be online updated£»
*Li battery, continue working time up to 7 hours;
*Other assistant function;
*Display freeze;
*Automated echo degree;
*Angles and K-value;  
*Lock and unlock function of system parameters;
*Dormancy and screen savers;   
*Electronic clock calendar ; 
*Two gates setting and alarm indication;
*High-speed capture and very low noise;
*DAC¡¢AVG; Solid metal housing (IP65);
*Provides high contrast viewing of the waveform from bright, direct sunlight to completae darkness and easy to read from all angles;
*Powerful pc software and reports can be export to excel;

Specifications:
Designation
Technical Data
Range of scanning (mm)
Range of scanning (mm)£º2.5¡«60000(Steel Longitudinal wave)
Steps: 2.5,5,10,20, 30,40,50,60,70,80,90, 100,150,200, 250, 300, 350, 400, 450,500,600,700,800,900,1000,2000,3000,4000,5000,6000
Adjusting step: 0.1mm£¨2.5 mm¡«99.9mm£©£¬1mm£¨100mm¡«10000mm£©
D-delay (ms)
D-delay (ms)£º-20¡«+3400
Steps: -20,-10,0.0, 10, 20, 50,100,150,200,250,300,350,400,450,500, 600,
700,800,900,1000,1500,2000,2500,3000,3400.
Adjusting steps: 0.1£¨-20ms¡«999.9ms£©£¬1£¨1000ms¡«3400ms£©
P-delay (ms)
P-delay£º0.0¡«99.99
Adjusting steps: 0.01
MTLVEL£¨m/s£©
MTLVEL£º1000¡«9999
7 fixed levels: 2260,2730,3080,3230,4700,5920,6300
Adjusting steps:1
Working mode
Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission(transmission probe)
FrequencyRange (MHz)
0.4¨C20
Gain adjustment (dB)
0¡«110
Adjusting step: 0.0£¬0.2£¬0.5£¬1£¬2£¬6£¬12
Reject
0%¡«80% of screen height, step: 1%
Vertical linear error
Vertical linear error is not more than 3%
Horizontal linear error
Not more than 0.2% in the scanning range
Sensitivity Leavings
¡Ý62 dB
Dynamic range
¡Ý32dB
Alarm
Three modes, i.e. forbidden wave, loss wave and auto
Monitoring door
2, expressed by bold transverse line, whose start, width and height are adjustable.
Adjusting range of start (mm): horizontal pixel 0~208, the displayed value is relative with the scanning range.
Step: value in mm corresponding to a pixel (relative with the scanning range)
Adjusting range of width (mm): horizontal pixel 4¡«212, the displayed value is relative with the scanning range.
Step: value in mm corresponding to a pixel (relative with the scanning range)
Adjusting range of height: 2%~90% of vertical graduation
Step graduation: 1%
Display  
Display: high-brightness lattice 
A-Scan display area
Full screen or local
A-Scan display freezing and de-freezingA-Scan filling
Data save
300 A-Scan images (including setting of instrument)
30000 values of thickness (300 sets)
Standard communication interface with PC
RS232
Measuring unit
mm/inch
Battery
Li battery 4¡Á3.6V4800mAh
Power adaptor
Input 100V¡«240V/50Hz¡«60Hz
Output 9V¡«12VDC/1.5A
Working temperature
-20¡æ¡«70¡æ
Working humidity
20%¡«90%
Port type
BNC
Dimension (mm)
240¡Á180¡Á50
Weight (kg)
1.8
Standard configurations
Designation
Quantity
Main unit
1
1.5A/9V power adaptor
1
probe connecting cable
2
Carrying case
1
Instruction manual
1
Straight probe
F20 2.5MHz (One)
Angle probe
2.5MHz10¡Á10K2 (One)
Beijing TIME Haofang Technology Co., Ltd. All Rights Reserved
Tel: +86-10-61199378 Fax: +86-10-61199378 E-mail:1829881916@qq.com ¾©ICP±¸11029437ºÅ-2 Sign in