 Features: 
 *Automated gain¡¢Peak Hold and Peak Memory£»  
*Automated display precise flaw location(Depth d¡¢level p¡¢distance s¡¢amplitude¡¢sz dB¡¢§æ)£»  
*Ten independence setup, any criterion can be input freely, we can work in the scene without test block£»  
*Big memory of 300 A graph and 30000 thickness value.  
*Gate and DAC alarm£»Acoustic-Optical alarm;  
*RS232 port£¬communication with pc is easy£»  
*The embeded software can be online updated£»  
*Li battery, continue working time up to 7 hours;  
*Other assistant function;  
*Display freeze;  
*Automated echo degree;  
*Angles and K-value;    
*Lock and unlock function of system parameters;  
*Dormancy and screen savers;     
*Electronic clock calendar ;   
*Two gates setting and alarm indication;  
*High-speed capture and very low noise;  
*DAC¡¢AVG; Solid metal housing (IP65);  
*Provides high contrast viewing of the waveform from bright, direct sunlight to completae darkness and easy to read from all angles;  
*Powerful pc software and reports can be export to excel;  
 Specifications:
  
| 
 Designation  | 
 Technical Data  |  
| 
 Range of scanning (mm)  | 
 Range of scanning (mm)£º2.5¡«60000(Steel Longitudinal wave) Steps: 2.5,5,10,20, 30,40,50,60,70,80,90, 100,150,200, 250, 300, 350, 400, 450,500,600,700,800,900,1000,2000,3000,4000,5000,6000 Adjusting step: 0.1mm£¨2.5 mm¡«99.9mm£©£¬1mm£¨100mm¡«10000mm£©  |  
| 
 D-delay (ms)  | 
 D-delay (ms)£º-20¡«+3400 
Steps: -20,-10,0.0, 10, 20, 50,100,150,200,250,300,350,400,450,500, 600, 
700,800,900,1000,1500,2000,2500,3000,3400. 
Adjusting steps: 0.1£¨-20ms¡«999.9ms£©£¬1£¨1000ms¡«3400ms£©  |  
| 
 P-delay (ms)  | 
 P-delay£º0.0¡«99.99 
Adjusting steps: 0.01  |  
| 
 MTLVEL£¨m/s£©  | 
 MTLVEL£º1000¡«9999 
7 fixed levels: 2260,2730,3080,3230,4700,5920,6300 
Adjusting steps:1  |  
| 
 Working mode  | 
 Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission(transmission probe)  |  
| 
 FrequencyRange (MHz)  | 
 0.4¨C20  |  
| 
 Gain adjustment (dB)  | 
 0¡«110 
Adjusting step: 0.0£¬0.2£¬0.5£¬1£¬2£¬6£¬12  |  
| 
 Reject  | 
 0%¡«80% of screen height, step: 1%  |  
| 
 Vertical linear error  | 
 Vertical linear error is not more than 3%  |  
| 
 Horizontal linear error  | 
 Not more than 0.2% in the scanning range  |  
| 
 Sensitivity Leavings  | 
 ¡Ý62 dB  |  
| 
 Dynamic range  | 
 ¡Ý32dB  |  
| 
 Alarm  | 
 Three modes, i.e. forbidden wave, loss wave and auto  |  
| 
 Monitoring door  | 
 2, expressed by bold transverse line, whose start, width and height are adjustable. 
Adjusting range of start (mm): horizontal pixel 0~208, the displayed value is relative with the scanning range. 
Step: value in mm corresponding to a pixel (relative with the scanning range) 
Adjusting range of width (mm): horizontal pixel 4¡«212, the displayed value is relative with the scanning range. 
Step: value in mm corresponding to a pixel (relative with the scanning range) 
Adjusting range of height: 2%~90% of vertical graduation 
Step graduation: 1%  |  
| 
 Display    | 
 Display: high-brightness lattice  |  
| 
 A-Scan display area  | 
 Full screen or local 
A-Scan display freezing and de-freezingA-Scan filling  |  
| 
 Data save  | 
 300 A-Scan images (including setting of instrument) 
30000 values of thickness (300 sets)  |  
| 
 Standard interface   | 
 RS232 for communication with PC  |  
| 
 Measuring unit  | 
 mm/inch  |  
| 
 Battery  | 
 Li battery 4¡Á3.6V4800mAh  |  
| 
 Power adaptor  | 
 Input 100V¡«240V/50Hz¡«60Hz 
Output 9V¡«12VDC/1.5A  |  
| 
 Working temperature  | 
 -20¡æ¡«70¡æ  |  
| 
 Working humidity  | 
 20%¡«90%  |  
| 
 Port type  | 
 BNC  |  
| 
 Dimension (mm)  | 
 240¡Á180¡Á50  |  
| 
 Weight (kg)  | 
 1.8  |    |